Customization: | Available |
---|---|
Media: | Air |
Temperature: | Ordinary Temperature |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. The working pressure of the product is 0.1MPa ~ 0.7MPa, and the medium is air after oil and water removal.
2. When the working voltage of the solenoid valve is 85% of the rated voltage under the nominal air supply pressure of the product, the opening response time of the electromagnetic pulse valve shall be less than 0.03s.
3. When the working air source pressure is 0.1MPa, the pulse valve can be closed.
4. The product shall be able to withstand the air supply pressure of 0.8MPa.
5. Under the specified environmental conditions, the insulation resistance of the electromagnetic coil to the shell shall be greater than 1m Ω.
6. Under the condition that the room temperature is 5 ° C ~ 35 ° C and the relative humidity is not more than 85%, the electromagnetic coil can withstand the voltage of 50Hz and 250V to the shell for 1min without breakdown.
7. The electromagnetic pulse valve shall be able to work normally after being subjected to vibration with frequency of 20Hz, full amplitude of 2mm and duration of 30min.
8. Under normal use conditions, the accumulated service life of the diaphragm shall be more than 800000 times.
9. There is no obvious coating peeling, scratch, burr and other damage on the surface of the valve.
Specification:
Valve Parts in Contact with Fluids
|
||
Body
|
Brass
|
303/304 Stainless Steel
|
Seals and Discs
|
NBR or Cast UR
|
|
Core Tube
|
305 Stainless Steel
|
|
Core and Plugnut
|
430F Stainless Steel
|
|
Springs
|
302 Stainless Steel
|
|
Shading Coil
|
Copper
|
Silver
|
Stem
|
PA (Normally Open)
|
|
Note: All 1/8" NPT Normally Open valves contain CA. All 1/4" NPT Normally Open valves contain PA.
|